A solar array that is underperforming rarely says so on its own. A failing cell, a sub-string that has dropped out or an overheating connection can sit unnoticed for months, quietly losing output and, in the worst cases, building towards a safety problem.

Thermography finds those faults because they show up as heat. A ground-based solar panel thermal inspection uses a calibrated radiometric thermal camera, carried by a thermographer on foot, to read the surface temperature of every module in view and pick out the cells, sub-strings, modules and junction boxes running warmer than their neighbours. On ground-mounted commercial and utility arrays, solar carports and canopies, that view is close and detailed, and each thermogram is paired with a visual photograph of the same modules. Where a string layout is available, every finding is placed on it, so the maintenance team can walk straight to the module concerned. Every survey is planned around the conditions IEC 62446-3:2017 sets out, because a thermal image of a solar array is only as reliable as the sunlight and the load behind it, and every finding is analysed and classified by our Level 3 thermographer.

This post is for asset owners, operations and maintenance teams and facilities managers of commercial and utility arrays. It explains what a camera on the ground can and cannot see, the conditions the survey has to wait for, and how a Level 3 report classifies what it finds, so you know what you are buying before you commission it. A separate post covers string-level electrical testing, which measures what the camera cannot.

Page Summary

  • Faults on a working solar array show as heat, because energy a cell cannot deliver as current is dissipated instead.
  • From the ground, a calibrated radiometric thermal camera reads ground-mounted rows, carports and canopies in close detail.
  • IEC 62446-3:2017 conditions: in-plane irradiance of 600 W/m² or more, stable sky, low wind and the array under load.
  • Reflections, shading and soiling are separated from genuine anomalies against the visual images.
  • Every finding carries an IEC 62446-3 Class of Abnormality; arrays needing a drone go to Drone Media Imaging.

Ground-Based Thermography in Commercial Solar Panel Inspections

What a ground-based camera sees across a working solar array, and how findings are classified.

Thermal image of ground-mounted solar modules, one cell anomaly brighter than the evenly warm cells around it

Reading an Array from the Ground

Why faults on a solar array show as heat

A solar module absorbs most of the sunlight that reaches it. Part of that energy leaves as electricity; the rest is shed as heat. A healthy module in a working string settles at an even temperature across its cells, and its neighbours settle at much the same temperature.

When a cell is cracked, a solder joint has degraded or a sub-string has been bypassed, that part of the module stops delivering its share of the current. The sunlight it still absorbs has to go somewhere, so it is dissipated as heat and the area runs warmer than the cells around it. A thermal camera sees that difference directly, across many modules in a single view.

What a camera on the ground can see

From the ground, the camera sees what it has a clear, usable line of sight to. On ground-mounted rows, solar carports and canopies, that means each module can be viewed at close range, with enough detail to place an anomaly on a single cell and to photograph the same module in visible light alongside it.

The limits are just as physical. A module is a sheet of glass, and from the wrong angle it reflects the sky, the sun, nearby structures or the thermographer instead of showing its own temperature, so every view is taken at an angle chosen to avoid those reflections. Arrays the camera cannot view at a usable angle from the ground, such as most roof-mounted systems, or plants so large that coverage from the air is the practical route, need a drone. That work is carried out by Drone Media Imaging, and Thermography Services (UK) can analyse and certify the data it captures.

Thermography also reads heat, not electrical output. It identifies thermal patterns consistent with cell, sub-string, module and connection faults; it does not measure what each string is producing, and some electrical conditions leave no thermal trace at all.

The conditions IEC 62446-3 sets out

Because the heat comes from the sunlight, the survey has to wait for the right sunlight. IEC 62446-3:2017, the international technical specification for outdoor infrared thermography of PV modules and plants, sets requirements for the measurement equipment, the ambient conditions, the inspection procedure and the report. In practice that means:

  • strong sunlight on the modules, with the irradiance measured in the plane of the array at 600 W/m² or more;
  • stable conditions, without passing cloud changing the sunlight from one image to the next, and with low wind;
  • the array operating normally under load, because an array that is switched off or curtailed heats evenly and hides the faults the survey is looking for;
  • dry module surfaces and a camera fit for the task, with its calibration documented.

The irradiance is recorded through the survey, not once at the start. The temperature differences in the classification guidance are stated at a nominal irradiance higher than most UK surveys are carried out under, so each measured difference is projected to that nominal level before it is compared, and the irradiance behind every finding is published in the report so a reader can check the projection.

Telling a fault from something that only looks like one

Many warm patterns on an array are not faults. Reflections and glare, shade from a fence, a post or the row in front, bird droppings and patchy soiling all produce warm spots of their own. Some modules carry several junction boxes that show small, regularly placed warm signatures under strong sunlight as part of normal operation. Across a long survey the whole array warms as the sun climbs, which moves the baseline without indicating any fault.

Each thermogram is therefore read against its visual image, its viewing angle and the conditions at the moment it was taken, and against modules operating normally in the same image. Patterns explained by reflection, shading or soiling are recorded as such and kept apart from genuine anomalies. Soiling is reported as an observation in its own right, never assumed to be the cause of a cell anomaly.

How a Level 3 report classifies the findings

Under IEC 62446-3, every abnormality is given a Class of Abnormality. Class 1 is no abnormality. Class 2 is a thermal abnormality, where the cause should be checked and, if necessary, rectified within a reasonable period. Class 3 is a safety-relevant thermal abnormality, which calls for operation to be interrupted promptly and the cause checked and rectified.

The specification illustrates the classes with example conditions, such as a single cell with a temperature difference, a sub-string in open circuit, a heated junction box or a module with broken front glass. Each finding is matched to the nearest condition on its evidence, and where a finding has no direct equivalent among the examples, the report says so and states the basis of the class it was given. Alongside the class, the report states what each finding means for the operation of the array: a safety concern, a loss of output, or a condition likely to progress before the next inspection.

Every finding is written in qualified language. A cell anomaly indicates, or is consistent with, a condition; the report points to the electrical contractor or maintenance team best placed to investigate it and never prescribes the repair. The inspection level, any declared deviation from the specification and the limitations of the survey are stated plainly, and every report is written and certified by our Level 3 thermographer.

From the ground, from the air, or from data you already hold

Where an array can be surveyed from the ground, Thermography Services (UK) carries out the solar panel thermal inspection and the analysis. Where it needs a drone, Drone Media Imaging flies it. Where you already hold thermal data from your own team or operator, our solar PV thermography report writing service analyses it, classifies every finding and certifies the result.

IEC 62446-3:2017

Outdoor PV Thermography

IEC 62446-3:2017 is the International Electrotechnical Commission’s technical specification for outdoor infrared thermography of photovoltaic modules and plants in operation. It lays down requirements for the measurement equipment, the ambient conditions, the inspection procedure, the inspection report and personnel qualification, and gives a matrix of example thermal abnormalities as a guideline for classification.

It distinguishes a simplified inspection, which reads thermal patterns without determining temperatures, from a detailed inspection, which determines absolute temperatures and may classify patterns beyond its examples. It asks that any known deviation or limitation be noted in the report. That is why our reports state the inspection level, the conditions and any deviation, and why surveys and analysis are described as aligned with the specification rather than as compliant with it.

Domestic solar panel inspections to IEC62446 in Sussex and Kent
Get in Touch

Plan a Ground-Based Survey

Tell us about the array: where it is, how it is mounted, how large it is, whether a string layout is available and what the report is for. We will say whether it can be surveyed from the ground, plan the visit around the conditions IEC 62446-3 sets out and send a proposal and quotation. Where the array needs a drone, we will point you to Drone Media Imaging. Every report is written and certified by our Level 3 thermographer.